- Departmental Considerations 15%
- Cleaning, Decontamination and Disinfection 21%
- Preparation and Packaging 21%
- Sterilization Process 21%
- Sterile Storage, Transport and Inventory Management 9%
- Patient Care Equipment and Distribution 5%
- Professional Development and Human Relation Skills 8%
Free · 2026 · 25-question practice exam Free CRCST practice exam: 25 questions with answers
This free CRCST practice exam has 25 questions in the proportions of HSPA's current Content Outline: Departmental Considerations (15%), Cleaning, Decontamination and Disinfection (21%), Preparation and Packaging (21%), Sterilization Process (21%), Sterile Storage and Inventory (9%), Patient Care Equipment (5%), and Professional Development (8%). It keeps the pace of the real 150-question, 3-hour Prometric exam (30 minutes for 25 questions), with every answer explained when you submit. The clock starts at your first answer. Submit any time to see your score by domain and every answer explained.
- No sign-up
- 25 questions, 30 min clock
- Every answer explained
| Domain | Questions | Real exam |
|---|---|---|
| Departmental Considerations | 4 | 15% |
| Cleaning, Decontamination and Disinfection | 6 | 21% |
| Preparation and Packaging | 5 | 21% |
| Sterilization Process | 5 | 21% |
| Sterile Storage, Transport and Inventory Management | 2 | 9% |
| Patient Care Equipment and Distribution | 1 | 5% |
| Professional Development and Human Relation Skills | 2 | 8% |
Question 1 of 25
A technician is manually cleaning a reusable suction cannula that has a narrow lumen. Which technique best follows recommended practice?
Answer: C. The brush must contact the walls along the full length, and flushing with detergent, brushing, then flushing again carries the loosened soil out.
Why not A: A brush that doesn't contact the lumen walls provides no friction and leaves soil and biofilm behind. A single flush also skips the required steps.
Why not B: Brushing a dry lumen and flushing only at the end reverses the sequence. The lumen should be flushed first so loose soil is carried out before brushing.
Why not D: An oversized brush can damage the lumen and may not pass through. Partial insertion from each end can leave the middle of the lumen uncleaned.
Remember: Match the brush diameter and length to the lumen so it contacts the walls and exits the far end, and flush with detergent before and after brushing.
Question 2 of 25
A delivery of commercially sterile peel-packed catheters arrives in corrugated shipping cartons. The sterile storage shelves are nearly full. What should the technician do?
Answer: D. Items are taken out of external shipping cartons in the break-out area and checked against the order before they enter clean or sterile areas.
Why not A: External shipping cartons carry dust, insects and microbes and must never enter sterile storage, even on the bottom shelf.
Why not B: Opening the cartons in sterile storage still brings contaminated cardboard into the restricted area.
Why not C: Nothing is stored on the floor of sterile storage, and the cartons should not enter the area at all.
Remember: Corrugated shipping cartons stay in the break-out area and never go into sterile storage.
Question 3 of 25
A steam sterilizer has a confirmed positive biological indicator, and the supervisor orders a recall. Which documentation is most essential for identifying every affected package and tracing items that have already been used?
Answer: C. The load control number (lot number) identifies the sterilizer, cycle and date, and the load record lists every item, so packages can be retrieved and traced to cases or patients.
Why not A: The printout confirms cycle parameters, but it does not list the items in the load or where they went.
Why not B: The Bowie-Dick test checks air removal and sterilant penetration in an empty chamber of a prevacuum sterilizer, and it contains no information about load contents.
Why not D: The maintenance log documents service history, not which items were processed in a specific load.
Remember: Load control numbers tied to complete load records make recalls and patient traceability possible.
Question 4 of 25
While pouring alkaline detergent into a sink in decontamination, a technician gets a splash in one eye. What should the technician do first?
Answer: C. Immediate, continuous flushing for about 15 minutes limits chemical injury. Reporting and the incident report follow.
Why not A: The SDS is useful later, but looking it up first wastes critical seconds. The eye must be flushed at once.
Why not B: Delaying the flush while reporting allows more chemical damage. Flushing always comes first.
Why not D: A brief rinse at a utility sink is not adequate, and stopping when the stinging eases can leave chemical in the eye.
Remember: After a chemical splash to the eye, flush at the eyewash station immediately for 15 minutes, then report.
Question 5 of 25
Which enzyme in an enzymatic detergent breaks down blood and other protein-based soil?
Answer: B. Protease digests proteins, which makes it the key enzyme for removing blood and tissue.
Why not A: Lipase breaks down fats and lipids, not protein soil.
Why not C: Amylase breaks down starches and carbohydrates, not proteins such as blood.
Why not D: Catalase breaks down hydrogen peroxide and is not the enzyme used to digest protein soil on instruments.
Remember: Protease breaks down protein (blood), lipase breaks down fat, and amylase breaks down starch.
Question 6 of 25
A decontamination technician opens a returned tray and finds heavily dried blood on the instruments and several hemostats left closed and ratcheted. What is the best action?
Answer: C. The technician opens the instruments and cleans them per IFU (presoak if allowed), and reporting lets the user department be educated to prevent recurrence.
Why not A: Ignoring the problem allows the poor practice to continue, which harms instruments and threatens cleaning effectiveness.
Why not B: Dried soil is not a reason to discard reusable instruments; most can be cleaned with proper soaking and brushing.
Why not D: Soiled items should not travel backward out of decontamination, and returning the tray delays processing and spreads contamination.
Remember: Clean what arrives properly, and report inadequate point-of-use treatment so the cause is corrected.
Question 7 of 25
A technician in decontamination is wearing a fluid-resistant gown, face shield and utility gloves. She needs to check a count sheet that is only available on a computer in the preparation and packaging area. What should she do?
Answer: A. Staff take off decontamination PPE before leaving the soiled area and clean their hands so contamination does not move into clean areas.
Why not B: Soiled items must never travel into clean areas; workflow moves only from dirty to clean.
Why not C: The gown and face shield are contaminated decontamination PPE and must not be worn into clean areas.
Why not D: Contaminated PPE carries microorganisms into the clean area even if she touches nothing, breaking dirty-to-clean workflow.
Remember: Decontamination PPE comes off before leaving the soiled area, followed by hand hygiene, so nothing contaminated moves into clean areas.
Question 8 of 25
A lead technician is setting up the routine biological indicator test in a production load of a dynamic-air-removal steam sterilizer. Where should the BI process challenge device (PCD) be placed?
Answer: D. The area over the drain is the coldest and hardest for steam to reach, and routine tests are run in a full load to represent real conditions.
Why not A: The PCD is a separate test device placed in the most challenging chamber location, not packed inside a set.
Why not B: An empty chamber is used for qualification testing after installation or major repair, not for routine load monitoring.
Why not C: Air and condensate collect low near the drain, so the top shelf is not the most challenging location.
Remember: For routine steam testing, place the BI PCD on the bottom shelf, front, over the drain, in a full load.
Question 9 of 25
A technician weighs a spine set. The instruments weigh 21.5 lb, the empty rigid container weighs 5 lb, and the internal basket and silicone mat together weigh 1 lb. According to AAMI ST79, what should the technician do?
Answer: D. 21.5 lb + 5 lb + 1 lb = 27.5 lb, which exceeds the 25-lb (11.3 kg) AAMI limit. The set should be split or reconfigured per policy and the container IFU.
Why not A: Extra dry time doesn't make an overweight set acceptable; cycle parameters must follow the container and sterilizer IFUs.
Why not B: The 25-lb limit applies to the whole package, including the container and any inserts, not just the instruments.
Why not C: Rigid containers aren't exempt; the container weight counts toward the 25-lb total.
Remember: A complete instrument set, including its container or wrap and its inserts, should not exceed 25 lb (11.3 kg).
Question 10 of 25
When sterile items are placed on the top shelf of a storage unit, what is the minimum clearance that must be kept between the top of the stored items and the sprinkler heads?
Answer: B. Keeping at least 18 inches below sprinkler heads lets the spray pattern reach a fire and is a fire-safety requirement in sterile storage.
Why not A: Two inches is the minimum distance shelving should be kept from outside walls, not the sprinkler clearance.
Why not C: Eight to ten inches is the clearance for the lowest shelf above the floor, not the clearance below sprinklers.
Why not D: About 5 inches is the commonly taught clearance from the ceiling. Sprinkler heads need the larger 18-inch clearance.
Remember: Keep stored items at least 18 inches below sprinkler heads, 8-10 inches above the floor and 2 inches from outside walls.
Question 11 of 25
A technician is assembling a laparoscopy set that includes a rigid telescope and a fiber-optic light cable. The set also contains heavy retractors. Which assembly is correct?
Answer: D. The telescope needs its own protective holder or tray, and the cable must be coiled loosely per IFU to avoid breaking the glass fibers.
Why not A: The heavy-on-bottom rule protects instruments; it never means stacking weight on a telescope, which can bend the shaft or crack the lenses.
Why not B: Peel pouches aren't placed inside wrapped sets or containers unless the IFU allows it, and a pouch wouldn't protect the telescope from heavy instruments.
Why not C: Tight coiling breaks the glass fibers, and pressure on the telescope can damage it.
Remember: Rigid telescopes go in protective holders away from heavy instruments, and light cables are coiled loosely to protect the fibers.
Question 12 of 25
Which equipment should be available at each workstation in the preparation and packaging area so technicians can inspect instruments for residual soil and damage?
Answer: D. Lighted magnification lets technicians see small amounts of soil, cracks, burrs and misalignment that the eye can miss.
Why not A: Overhead lighting alone often misses fine soil in serrations and box locks and small cracks or burrs.
Why not B: A shared flashlight does not provide the magnification needed for detailed inspection at every workstation.
Why not C: Light tables are used to find holes in reusable woven wraps, not to examine instrument surfaces for soil and damage.
Remember: Instrument inspection in the clean work area requires good lighting with lighted magnification at the workstation.
Question 13 of 25
After the required incubation, a technician reads a steam test BI from a PCD as negative (no growth). The unprocessed control BI from the same lot, incubated alongside it, also shows no growth. How should the technician interpret these results?
Answer: D. The control must grow to prove the spores were viable and the incubator worked. Without that, the negative test result has no meaning.
Why not A: The control was never sterilized, so it should grow. No growth in the control means the test BI result cannot be trusted.
Why not B: A control BI from the same lot is incubated whenever test BIs are run, not just for implant loads.
Why not C: A negative control does not show a sterilizer failure. It shows that the test itself is invalid, possibly from nonviable spores or an incubator problem.
Remember: The control BI must grow; if it doesn't, the test BI result is invalid and must be investigated and repeated.
Question 14 of 25
A technician confirms that a heat-sensitive camera head is completely dry, seals it in a paper-plastic peel pouch and loads it into a hydrogen peroxide gas plasma sterilizer. The sterilizer cancels the cycle. What is the most likely cause?
Answer: C. Paper is cellulose, which absorbs peroxide and causes cycle aborts. Tyvek-plastic pouches or polypropylene wrap should be used.
Why not A: Paper is still cellulose regardless of how many layers are used, and most manufacturers' IFUs do not call for double pouching in hydrogen peroxide systems. Use only compatible synthetic materials such as Tyvek-plastic pouches or polypropylene wrap.
Why not B: Tyvek-plastic peel pouches are made for hydrogen peroxide systems. The problem is the paper, not pouches in general.
Why not D: Hydrogen peroxide breaks down to water and oxygen and needs no aeration after the cycle; aeration is an EO requirement and is never needed before a cycle.
Remember: Keep all cellulose (paper, linen, cotton) out of hydrogen peroxide sterilizers and make sure every item is completely dry.
Question 15 of 25
An OR charge nurse calls sterile processing, clearly upset, because a tray arrived without its needle holder and the case was delayed. What is the best response by the technician who takes the call?
Answer: C. Service recovery means listening, apologizing, fixing the problem quickly, following up to confirm it was resolved and documenting the event.
Why not A: Redirecting the nurse delays the fix while the patient is in the OR; the immediate need must be met first.
Why not B: An apology alone does not deliver the missing instrument or confirm the problem was resolved.
Why not D: Blaming a coworker does not solve the nurse's problem and reflects poorly on the department.
Remember: Service recovery is not just an apology: listen, apologize, fix the problem, follow up and document.
Question 16 of 25
While pulling a case cart, a technician sees that the next case on the OR schedule is a right total hip arthroplasty. What does the term arthroplasty mean?
Answer: D. Arthr/o means joint and -plasty means surgical repair or reshaping, so a total hip arthroplasty reconstructs or replaces the hip joint.
Why not A: Looking inside with a scope is indicated by -scopy (arthroscopy).
Why not B: Removal is indicated by the suffix -ectomy (arthrectomy), not -plasty.
Why not C: Cutting into a structure is indicated by -otomy (arthrotomy).
Remember: -plasty means surgical repair or reshaping; do not confuse it with -ectomy (removal), -otomy (cutting into) or -scopy (viewing with a scope).
Question 17 of 25
A disinfectant's label claims it is tuberculocidal (kills Mycobacterium tuberculosis) but makes no sporicidal claim. Based on relative microbial resistance, which organism should NOT be assumed to be killed by this product at its labeled contact time?
Answer: D. Bacterial spores are more resistant than mycobacteria. A product proven against TB but lacking a sporicidal claim cannot be relied on to kill spores.
Why not A: Fungi rank below mycobacteria in resistance and are expected to be killed by an intermediate-level tuberculocidal product.
Why not B: Vegetative bacteria are far less resistant than mycobacteria and are killed by tuberculocidal products.
Why not C: Enveloped viruses are among the least resistant organisms, so a product that kills mycobacteria is expected to inactivate them.
Remember: Resistance runs from prions to bacterial spores to mycobacteria and down to enveloped viruses, so a tuberculocidal claim does not mean the product kills spores.
Question 18 of 25
A technician needs to move a heavy wrapped instrument set from a low shelf onto a nearby transport cart. Which technique best protects her back?
Answer: C. Bending the knees, keeping the load close and using the leg muscles reduces strain on the spine. She should then turn by pivoting her feet rather than twisting.
Why not A: Fast lifting combined with twisting is a common cause of back injury. Pivot with the feet instead of rotating the spine.
Why not B: Bending at the waist puts the load on the lower back, a leading cause of lifting injuries. Proper body mechanics bend at the knees.
Why not D: Holding a load away from the body greatly increases the force on the back and shoulders. Loads should be kept close to the body's center.
Remember: Lift with bent knees and the load held close, never twist, and store heavy sets between knee and shoulder height to reduce injury risk.
Question 19 of 25
While inspecting a cleaned enteral feeding pump, a technician finds that the power cord insulation is frayed near the plug and the inner wires are visible. The pump otherwise works. What is the appropriate action?
Answer: A. Frayed or damaged cords make equipment out of compliance. The pump is tagged out of service and repaired by Biomedical Engineering.
Why not B: Taping does not restore safe insulation and hides the defect. Damaged cords are a shock and fire hazard that must be repaired by qualified staff.
Why not C: Swapping parts is a repair outside the technician's role. It also leaves an undocumented defect and may create a second noncompliant device.
Why not D: Staff could still plug in the damaged cord. Equipment with a known electrical defect must not be distributed.
Remember: Any frayed cord, damaged plug or cracked housing means the device is tagged and sent to Biomedical Engineering, never patched and distributed.
Question 20 of 25
A washer-disinfector cart has just been pulled into the prep area, and the trays are still very hot. A technician is in a hurry to start the set needed for the next case. What is the safest approach?
Answer: C. Trays should cool enough to handle and inspect safely, and heat-protective gloves prevent burns when hot racks must be moved.
Why not A: Handling hot instruments with bare hands risks burns, and rushing increases the chance of dropping or damaging items.
Why not B: Thin exam gloves give no meaningful heat protection, so the technician risks burns from hot metal.
Why not D: Tap water rinsing in the clean area can leave mineral spots and residue on clean instruments and wets items that should be dry.
Remember: Carts and trays leaving a washer-disinfector are hot; let them cool and use heat-resistant gloves rather than rushing or cooling them with water.
Question 21 of 25
An EO cycle has finished its exposure phase, but aeration still has several hours to run. A surgeon's office calls asking for one of the items right away. What should the technician do?
Answer: C. Aeration removes toxic residual EO from items, and it must never be cut short, regardless of demand.
Why not A: Gloves do not protect the patient from residual EO left in the device material.
Why not B: A changed chemical indicator shows exposure to the process; it says nothing about removal of toxic EO residue.
Why not D: A negative BI confirms the kill, not that residual EO has been removed to safe levels.
Remember: EO items are not handled or released until the full IFU-specified aeration is complete.
Question 22 of 25
Which microorganism is used in biological indicators that monitor ethylene oxide (EO) sterilization cycles?
Answer: D. Bacillus atrophaeus spores are the BI organism for EO and also for dry heat.
Why not A: Mycobacteria are used to test whether disinfectants kill tuberculosis-type organisms, not to monitor sterilizers.
Why not B: C. difficile is a spore-forming pathogen of concern in infection prevention, but it is not a sterilization BI test organism.
Why not C: This organism is used for steam, hydrogen peroxide, ozone and peracetic acid processes, not EO.
Remember: Bacillus atrophaeus monitors EO and dry heat; Geobacillus stearothermophilus monitors steam and hydrogen peroxide.
Question 23 of 25
Which quality improvement approach focuses mainly on removing waste from a process, such as waiting, unnecessary motion, overprocessing and excess inventory?
Answer: C. Lean targets waste such as waiting, extra motion, overprocessing, defects and excess inventory, often using tools like 5S.
Why not A: Root cause analysis investigates the underlying system cause of a specific event; it is not a waste-elimination method.
Why not B: PDCA is a general four-step cycle for testing and carrying out changes; it is not defined by a focus on eliminating waste.
Why not D: Six Sigma focuses mainly on reducing variation and defects through its DMAIC steps, not primarily on removing waste.
Remember: Lean removes waste, Six Sigma reduces variation (DMAIC), and PDCA is a repeating Plan-Do-Check-Act improvement cycle.
Question 24 of 25
While assembling a microsurgery set, a technician needs to protect the delicate tips of a pair of microscissors during sterilization and handling. Which choice is correct?
Answer: C. Tip protectors should be vented, fit loosely and be compatible with the sterilization method so sterilant can reach the tips.
Why not A: A tight, non-vented cap blocks sterilant contact with the tips and traps moisture, which defeats sterilization.
Why not B: Rubber bands block sterilant from the surfaces underneath and keep the instrument closed instead of open.
Why not D: Tape covers the surfaces sterilant must contact and can leave adhesive residue on the instrument.
Remember: Tip protectors must be vented, loose-fitting and approved for the sterilization method being used.
Question 25 of 25
After a washer-disinfector cycle, inspection finds dried soil inside several Frazier suction tips, while the hemostats and basins in the same load are clean. The washer passed its last efficacy test. What is the most likely cause?
Answer: A. Lumens need direct flow from the washer's irrigation manifold, because spray arms cannot reach inside narrow channels.
Why not B: Placing concave surfaces facing down is correct loading practice and lets water drain; it would not leave soil inside lumens.
Why not C: Critical water is correct for the final rinse; the rinse water type does not explain soil left only inside lumens.
Why not D: Hinged instruments should be loaded open, and that has no effect on cleaning inside suction tip lumens.
Remember: Lumened items must be connected to the washer's irrigation ports; spray from the arms does not clean inside lumens.
CRCST practice exam FAQ
How many questions are on the HSPA CRCST exam?
150 multiple-choice questions in 3 hours (180 minutes) at a Prometric testing center. 125 are scored and 25 are unscored pretest questions mixed in with the rest. This free practice exam has 25 questions on a 30-minute clock at the real exam pace, and every question counts.
What score do you need to pass the CRCST exam?
HSPA scores the CRCST exam as pass or fail based on the number of scored items answered correctly and does not publish an exact percentage cut score. This free test compares your score against a 70% study benchmark; aim comfortably above it before scheduling at Prometric.
What is on the CRCST exam in 2026?
Seven weighted domains from HSPA's Content Outline: Departmental Considerations (15%), Cleaning, Decontamination and Disinfection (21%), Preparation and Packaging (21%), Sterilization Process (21%), Sterile Storage, Transport and Inventory Management (9%), Patient Care Equipment and Distribution (5%), and Professional Development and Human Relation Skills (8%).
Is this practice exam like the real CRCST exam?
It follows the exact 7-domain weights and pacing of the real HSPA exam. The questions are our own, written to the official outline and sterile processing references; HSPA does not release real exam questions. Every question includes explanations for every answer choice.
How should I use a CRCST practice exam?
Take all 25 questions in one timed sitting, then review every missed or guessed explanation and focus on your lowest-scoring domain before testing again. For a quick 10-question check across all seven domains, try our free CRCST readiness diagnostic.
Sources: HSPA, CRCST exam content outline, HSPA, 2026 certification handbook.
More free CRCST practice
- The free CRCST diagnostic test, with your score by domain →
- CRCST Departmental Considerations practice questions →
- CRCST Cleaning, Decontamination and Disinfection practice questions →
- CRCST Preparation and Packaging practice questions →
- CRCST Sterilization Process practice questions →
- CRCST Sterile Storage, Transport and Inventory Management practice questions →
- CRCST Patient Care Equipment and Distribution practice questions →
- CRCST Professional Development and Human Relation Skills practice questions →
The real HSPA CRCST: 150 questions (125 scored) in 3 h, prometric test centers (in person). Pass/fail on the number of scored questions you get right; HSPA doesn't publish the cut score. These are original practice questions, not questions from the real exam.